View Single Post
  #3   Report Post  
Peter Andrews
 
Posts: n/a
Default


"Mark Smith" wrote in message
m...
Hi,

I am having a problem with the downstairs lighting circuit which I
hope someone will be able to help me with.

For the past few weeks, the light circuit is blowing ramdomly, but can
be about 10 minutes or so. What is strange, is that this can happen
even with all the lights switched off.

I am finding it hard to understand the cause, as logically, a faulty
wire should exhibit predicatable results. I would appreciate any
advice or tips which i could try in order to reduce the area of
investigations. ONe room has a dimmer switch and the kitchen has a
halagon light, but the problem remains even with all the lights off.

Your help is warmly appreciated.

Regards
Mark


I had a similar problem recently - eventually I found a pinched live wire in
one ceiling fitting - my guess is that it occassionaly shorted to earth when
the fitting was hot. I suggest using a meggar but not everyone has one