View Single Post
  #6   Report Post  
Richard J Kinch
 
Posts: n/a
Default

TURTLE writes:

He said at any temp water supply from
33§F water the unit will supply 96§F to 140§F water all day long at
8.5 GPM.


Bunk.

32 deg F rising to 96 or 140, that's 64 to 108 BTUs per pound, or 534 to
901 BTUs per gallon, or 4540 to 7660 BTUs per minute at 8.5 gpm, or 272K to
460K BTUs/hr, assuming 100 percent efficiency, which equates to 80 to 135
kilowatts, or 333 to 563 amps of 240 VAC.

Does this unit come with a hookup to Niagara Falls, or perhaps the Alaskan
pipeline?