What are the walls made of. If it is just the metal building
outside skin, you will have a difficult time keeping the building
waterproof when you install fasteners. One method would be to
mount all electrical on Unistrut spanning from column to column.
Assuming this is not the case, it now depends on how you made the
inside walls. Interior steel liner panels would lend themselves
to surface mounted EMT. Wood or steel studs with wafer board or
other interior finish lends itself to about the same installation
that would be used in a residential install.