I have just moved into a flat with an Ariston Eurocombi. The boiler
has no pilot light and I have tried to light it with no success. THere
is a small reddish button in the middle of the control panel with an
image of a flame with an 'X' through it. I guess this is the ignition,


That's the flame failure reset button. If there's no gas it glows red.

but then I push it, it just feels springy. There's no click, no sound
and no sign of a flame. When I turn on the hot tap, I hear a click in
the boiler, but that's all.

Check the power's on and both bottons are in. It's possible the water
pressure in the system's too low, what's the pressure guage reading? Have a
listen to the flue outside, if you can't you hear the fan running that'll
confirm it. Top up via the filling loop. If it's above 1 bar on the scale,
and the flue fan's running, then the flow switch is not detecting the water
pump running, possibly the pump's seized through sitting for a while.

Keith


I know the boiler was working fine a week ago when I came to the flat,
but the previous tenants must have turned everything off and no I just
need to know how to fire the thing up again.