View Single Post
  #29   Report Post  
Jeff Wisnia
 
Posts: n/a
Default

Gina and Les Armstrong wrote:
"dadiOH" wrote in message
news:3Zk_d.5884$b_6.2918@trnddc01...

Gina and Les Armstrong wrote:


The toilet flange may be broken. The bolts slip into a keyhole slot
on the flange. If the flange is broken, you'll need to repair or
replace the flange.


I wonder if he could get a stainless steel flange?

--
dadiOH
____________________________




Or a brass coated one?

Les



If ever there was a thread where the expression "gilding a turd" applied
this is the one!

I've never had a problem with brass/bronze toilet hold down bolts
themselves. Over the years most of my angst over toilet hold downs has
been caused by cheap thin steel toilet flanges. If there's any moisture
around, even that caused by washing the floor around a toilet that's not
bedded on plumbers putty, the steel disappears from galvanic corrrosion
where it's in contact with the brass bolts, and the heads of those bolts
pull right through it.

Jeff

--
Jeffry Wisnia

(W1BSV + Brass Rat '57 EE)

"As long as there are final exams, there will be prayer in public
schools"