View Single Post
  #23   Report Post  
 
Posts: n/a
Default

obtain manuals D & J from local tech school. Be aware that doing
them by hand is a big pain in ass. Properly done each duct should be
followed and length and type of fittings, elbows, boots etc noted as
air resistance in elbows etc can dramaticly change length rating of
duct and thus air flow resistance.
stan