Question; why is part of the water that fills drained down the
overfill tube when it is filling up ?When I install a new filler, I
always just have all water run directly in the tank, not part in the
overflow ?

On Sun, 02 Jan 2005 16:29:18 -0700, "RJ"
wrote:

I had a similar problem with a FluidMaster.

If you've got hi pressure, and "certain toilets"
water going into the overflow pipe will keep the
flapper valve from seating.
( it also wastes a lot of water during the fill cycle )

I called FluidMaster.
They sent me a plastic screw-clamp
It reduces flow in the plastic hose that
feeds the overflow pipe.

Problem Solved !!


On Sun, 02 Jan 2005 13:56:15 GMT, George wrote:

I have a toilet with a Fluidmaster 400A fill valve (installed
by a plumber). It has (apparently) always had this
problem: The refill flow rate is too high. The bowl
fills and the refill flow keeps going and (apparently)
water goes over the "hump" in the trap and down the
drain. The water pressure here is not high. It seems
to me that too much water is coming out of the refill
tube and not enough is coming out elsewhere (wherever
that might be). Can this be adjusted?