Dave Plowman (News) wrote:


Perhaps you'd give the figures for a domestic combi that will fill a
standard bath with hot water in 3 minutes in winter? And of course, one
which doesn't store any water since that's no longer a true combi, but a
form of storage system...

Of course you can't, because such an animal doesn't exist.

Sad you didn't make a new year resolution to tell the truth and stop
peddling your usual misinformation.


Simple test fot the OP to try.

Time how long it takes to fill you bath from the cold tap alone with it
full on. If it is longer than three minutes then no amount of combi
power alone will do what you want. If the cold main is not up to the job
you will either need to upgrade it and/or accumulate water somewhere in
order to get the flow rate you desire.

--
Cheers,

John.

/================================================== ===============\