Thread: ticking smps
View Single Post
  #4   Report Post  
Ken
 
Posts: n/a
Default

BigTom wrote:
ive checked esr on all the caps and theyre ok.
ive got a another working monitor to test voltages/resistances etc.
ive read the sci.electronics.repair.of.smps.
are there any other good web sites where i can learn more about smps.


Jerry G. wrote:

This is not something that can be done over an email. It is the skill and
experience of using the proper tools and knowledge to be able to trace
through the operation of the supply, and to be able to check and or
try out
the various suspect components.

Many times in these supplies the electrolytic caps give problems. You can
use an ESR meter to test them.



Did you check for an over current condition causing the PS to shut down?