In a flat - all our radiators are hot at the top and cold in the
middle and the bottom.
I have been told this is not a trapped air problem - as they would be
cold at the top
We have a non combi boiler
Can anyone help come up with any ideas before I call an expensive
plumber
ie - how to flush radiators, or balance them????!!
Thanks
Rob
Pour this (
http://www.toolstation.com/search.html?searchstr=81717 ) or
something similar into header tank and leave for 2 weeks, radiators should
start working slowly.
empty system and refill could also add
http://www.toolstation.com/search.ht...earchstr=42011 for peace of
mind
Total cost £15, plumbers power flush depending on plumber £80 - £150
If it's really bad as you say all the rads are cold at the bottom, then
would drain the system, remove all rads wash out with hose pipe, replace
then add system cleaner for a week, drain and refill.