Jim Adney writes:
On Tue, 9 Nov 2004 16:41:01 -0500 "Charles Schuler"
wrote:
Disassemble the motor and just take in the rotor, so that they don't
have to do any significant work.
IF, it's a wound rotor motor. Most ac rotors are of the squirrel cage
variety.
I was wondering about that. Wouldn't a squirrel cage motor still have
the same magnetic properties? I'm not sure, but I'd bet that such a
rotor would still pass the growler test, but it's hard to imagine a
squirrel cage rotor with a short in it, which, I believe is what the
OP asked about.
By definition, a squirrel cage rotor is all shorts.
--- sam | Sci.Electronics.Repair FAQ Mirror:
http://repairfaq.ece.drexel.edu/
Repair | Main Table of Contents:
http://repairfaq.ece.drexel.edu/REPAIR/
+Lasers | Sam's Laser FAQ:
http://repairfaq.ece.drexel.edu/sam/lasersam.htm
| Mirror Sites:
http://repairfaq.ece.drexel.edu/REPAIR/F_mirror.html
Note: These links are hopefully temporary until we can sort out the excessive
traffic on Repairfaq.org.
Important: Anything sent to the email address in the message header is ignored.
To contact me, please use the feedback form on the S.E.R FAQ Web sites.