Thread: Soil fall angle
View Single Post
  #4   Report Post  
John Rumm
 
Posts: n/a
Default

Mark Begbie wrote:

I will be moving various bits of soil piping around and have drawn a
blank on fall rates. From a look, old cast iron pipes look to have a
generally steeper fall than modern (smooth) plastic piping [which
makes sense]. Also, soil piping seems to come with either 2.5 degree
or 22.5 degree branch adaptors. What are the regs / practice? Is it
2.5 degrees for plastic and 22.5 for iron?


IIRC building regs say the fall should be between 18 and 90mm per meter.

Have a look at approved document H:

http://www.odpm.gov.uk/stellent/grou...eg_600283.hcsp



--
Cheers,

John.

/================================================== ===============\
| Internode Ltd - http://www.internode.co.uk |
|-----------------------------------------------------------------|