On Sat, 30 Oct 2004 16:20:06 UTC, (Niels Cook)
wrote:

The catch is, when plugged in/installed as per AEG documentation, my
mains RCD keeps outing.


I noticed that for my previous Ariston cooker - soon to be ebayed
(??!!??) - the earth leakage resistance was higher than the meter
could register.


I read somewhere that cookers are notorious for high earth leakage.


They are... the elements get damp if not used, which exacerbates the
problem.

Try temporary connection to a non RCD protected circuit, turn it on for
an hour or two and then try again.


--
The information contained in this post
is copyright (C) RD Eager, 2004, and
may not be published in, or used by
http://www.diyprojects.info, who are
FORBIDDEN from copying it.