View Single Post
  #4   Report Post  
Dave Plowman (News)
 
Posts: n/a
Default

In article ,
Kevin wrote:
I have been having problems over the last couple of months with the
pilot light going out on my Glowworm SpaceSaver 50 Mk II boiler. It
started out happening every now and again and has got gradually worse.
What's happening now is that I can light the pilot light, and the
main burner fires up ok, but when the main burner switches off again
after a few minutes, the pilot light is also extinguished at the same
time. I am probably going to replace the thermocouple but is there
likely to be anything else I should be looking at ?


If you can remember, is the pilot light rather weedy compared to before?
If the boiler is lighting, it means the thermocouple is working. Could be
the slight pressure change as it lights blows the pilot light out.
Cleaning the pilot light jet would be my first try.

--
*Work like you don't need the money. Love like you've never been hurt.

Dave Plowman London SW
To e-mail, change noise into sound.