View Single Post
  #9   Report Post  
g
 
Posts: n/a
Default

The coil unit had 4 wire ends coming out to 3 contact points on the circuit
board. I just unwinded the coil to produce leading wire to the circuit
board, now it works fine.

Thanks for the help


"Geo" wrote in message
...
On Wed, 20 Oct 2004 15:39:04 -0400, "g" wrote:

the wires broke off from the circuit board to the coil unit


On my wife's Braun (UK Oral B) with timer, one [1] wire goes to a pad at
the end
of the pcb which is connected to the battery. The second [2] wire goes to
a pad
just next door to the right (not the pad marked x).
| |
| |
|[x] [2]|
| [1] |
|__________|

Geo