"nicoll" wrote
| I intend to replace a built in single oven with a double oven.
| The single oven is connected with 6mm T&E but does not have a
| local isolator. I will terminate the existing cable in a 45A
| cooker switch. How do I then connect the new double oven to the
| cooker switch? I don't know if the oven comes with a flex or
| not. Should there be a separate cooker outlet at the back of
| the oven housing to connect the oven to.
From the cooker switch you continue in 6mm fixed wiring to the back of (or
beside) the oven, where you use a cooker connection unit to make the final
connection to the oven, either using the oven's integral flex/cable or
another piece of 6mm.
Cooker connection unit (note these have a cable clamp for the flying lead,
they are not just ordinary junction boxes)
http://www.tlc-direct.co.uk/Products/MKK5045.html
or similar
Owain