View Single Post
  #6   Report Post  
IMM
 
Posts: n/a
Default

"Andy Hall" wrote in message
...
On Mon, 20 Sep 2004 18:50:13 +0100, "IMM" wrote:


"Andy Hall" wrote in message
.. .
On Mon, 20 Sep 2004 17:19:43 GMT, "VisionSet"
wrote:

I'm about to start the last major upheaval in my house.
Replaceing the ancient back-boiler.
The whole project may involve most of these:

Move or remove Water tank. I don't want it where it is it is in the

way
of a
subsequent minor loft conversion/over stairs mezzanine.

Move or remove water cylinder from landing to a cupboard in 3rd

bedroom
or
loft. Mainly for the same reason as above.

OK. This gives you the choice of

a) combi boiler (can be DIY install with notification to Building
Control)

b) pressurised sealed HW cylinder (must be professionally installed)

c) heatbank. ((as (a))


and:

d) Two cheap combi's to give excellent flow rates and give CH zoning of
pone boiler doing upstairs and one downstairs. Cost effective.


I was covering the sensible solutions.


But not well enough.

These all involve using mains cold water, so the first thing to check
is that the mains flow at the kitchen tap is adequate. Time filling
a bucket and calculate. If it's less than 20 litres/min as a rule
of thumb then you will need to upgrade the pipework if need be to the
street or all of these will be disappointing.

Install new boiler in 1/ under stairs, 2/ in loft 3/ somewhere else.

Though
exhaust of 1/ may interfere with subsequent garage updgrade at future

date.


You can get around that. Quite a number of boilers can use pairs of
50mm high temperature plastic waste pipe which can be routed over long
distances to avoid this issue.


Finally new gas fire in lounge to replace back boiler.

These are the major considerations, how else do I choose Combi boiler

or
stored water?

If you have the space for a cylinder or a heatbank (similar sizes)
then this will give far superior performance to a combi.


Depends on the hot water demands. An Alpha CB50 combi will give

excellent
performance with using only one bathrrom. How many bathrooms?


Mediochre would be a fairer description.


You have never seen one. Stop making things up.

This product delivers 50
litres of water at 60 degrees and then falls back to 11 lpm of 40
degree water.


Near 60 litres. Performance for one bath and shower is excellent. Well
worth considering.