View Single Post
  #2   Report Post  
Roy and Rosa
 
Posts: n/a
Default

I repaired the board. I have 2 bad ones to work on.
This post is the only one I found on the net about repairing this board. I
am surprised since there are plenty of posts about this board causing
problems.
Here is what I found wrong......for the next guy who has this problem.

board 1:
all zener diodes, D2-D7 were shorted. replaced (1N4738A 8.2v zener)
C2 had high ESR. replaced 220/63v

board 2:
Zener diodes, D2-D6 were shorted. replaced (1N4738A 8.2v zener)
D7 was open. replaced (1N4738A 8.2v zener)
C2 swollen and leaking. replaced 220/63v
C25 swollen and leaking replaced 333/63v
R2 burnt open. replaced 4.7k 1/2 watt
Q2 shorted. MPSA56 replaced with NTE159

Hope this helps. Roy

Has anyone diagnosed the problem with the ETC on a kenmore dryer? (dryer
runs when start button is pressed but stops when button is released) I'm

on
my third board in 3 years. I would like to repair the board. Have

checked
all items on component side of board but not on surface mount side.
Thanks Roy




---