"pmw" wrote in message ...
The program clock had a circuit diagram next to it with 60 settings detailed
inluding a pretty good description of each of the clock settings. THe
machine operates normally but as soon as the clock advances to a heating
setting (no. 12 on the dial) then the machine just continues cycling with no
heating. However if I manually advance the program to no 13. the machines
functions ok until the next heating phase and just hangs there. In other
words it fills with water and drains fine but at a heating stage it just
hangs. Any clues????
thanks for your interest
pmcdw
simple, I'd see if theres power reaching the heater element. But if
you dont know that much, I'd hesitate to recommend it, you could fry
yourself good and proper, then you might try and sue me, so dont do
it.
NT
|