I'm having a bit of a problem with the design of our new utility
room/conservatory and the building regs. people and was wondering if
anyone has any ideas.


If it is unheated, and you're not making the existing external walls
or doors between the heated part of our house and this extension any
worse (or if you're installing any doors, that they are external
quality and draught-stripped), then there is no limitation on the heat
loss through the extension; as per Approved Document L1, Sections 1.59
to 1.61.
--