View Single Post
  #6   Report Post  
Posted to rec.woodworking
dpb[_3_] dpb[_3_] is offline
external usenet poster
 
Posts: 1,325
Default 10" delta bench band saw

On 6/11/2021 2:15 AM, Rcn1973 wrote:
Yes everything runs smooth and band stays on track..i should say that it
did turn on and spin a bit the first rime i tried it but ever since it
blows a breaker the second it click to on..


So, you've got a path to ground somewhere -- either a bare wire in
connection box or the switch or something like that is/will be just a
mechanical fix or it's blown insulation off a winding...

You've just got to find where, specifically it is--internal or external
to the motor itself.

Start by taking looking at connections...you know it is at/from the
switch on or it would pop the breaker just plugging it in before turning
the switch on.


--