On Sat, 5 Jun 2021 12:35:49 -0200, dan posted for all of us to digest...


I picked up a one inch galvanized plug from Home Depot but it wasn't tapered
so it wouldn't fit. I went to a plumbing specialty supply store which had
brass, galvanized, and what they called "black metal" tapered one inch
plugs.


Make certain you have the correct plug. It might be a straight tread instead of
a pipe thread.

I bought the brass (it just seemed better) but it screwed down almost the
entire way into the plug hole so it weeps a little bit of water. I had only
put maybe two or three wraps of Teflon tape so maybe I need to wrap it more.


Use more and get some Megaloc. That will do it.

Testing the pressure switch is easy. What is the rating 30-50 or 40-60 or
something else. When the pressure drops low it turns the pump on when it
reaches the cutoff it shuts off. If you want take the cover off and measure
voltage and current at the load side. Make sure the switch and nipple don't
have any leaks. If you take the switch off make sure the nipple is clear, then
just replace the switch. Tape & Megaloc.

Maybe the pump overheated and went off on thermal and it took the time to
recover?

I am not familiar with your booster pump; why is it there? Could you post a pix
or diagram on a hosting site?

I am not a plumber but I have my own well so I have some familiarity with this.

Stay crusty...

--