Thread: Shed doors
View Single Post
  #8   Report Post  
Posted to rec.woodworking
knuttle knuttle is offline
external usenet poster
 
Posts: 194
Default Shed doors

On 5/19/2021 11:12 AM, DerbyDad03 wrote:
On Wednesday, May 19, 2021 at 8:18:03 AM UTC-4, wrote:
I have a 10 year old shed for my lawn tools, that is 2X constructions,
with standard particle board siding. While the outside was painted
immediately, the inside of the siding was left unpainted. The doors are
basically a sheet of siding with 2x4 around the edge of each door and in
an X pattern in the bottom half of the doors . The doors overlap the
floor joist and come to the bottom of the floor joist. The minimum
clearance under the shed is about 8" and is open on all four sides.

That area between the door and the joist has started to come a part
Since at this time the decomposition is minor, can i stave off the
replacement of the door by gluing the loose particles and painting that
are of the door?

Is there a better solution?


"standard particle board siding"

What do you mean by "standard particle board siding". There are numerous
materials that people refer to as "particle board", often incorrectly.


Do you perhaps mean that the OSB (?) on the interior bottom of the door is
beginning to look like this?


Yes I mean OSB, I can never remember what that is called. My vocabulary
has not gotten past particle board and plywood.

It is not decomposed as shown in the picture, only a large piece of wood
in the OSB is coming loose. The idea was to glue the piece back in, and
then paint, varnish, or something to prevent further degradation.


If so, I've never heard of regluing OSB. There are epoxies that are used to
stop rot and "rebuild" rotten wood, like window sills and thresholds.
Maybe that would work.

Perhaps you could spread epoxy over (and into) the area and then
clamp it to get it back to "flat". Using wax paper between the epoxy
and the boards used to make the clamping form will prevent the
form from sticking to the OSB (or whatever the actual material is).

Another option might be to cut off the damaged area and attach
a new "bottom" perhaps using pocket screws or a backer board
on the inside. Yes, there would be a seam that would need to be
sealed, but without more info (and perhaps a picture) it's tough to
offer specific solutions.



Beyond those couple of inches the OSB is in good conditions, the damage
is in the area between the door and the floor joist in the area where
the door overlaps when it is closed.

All of the suggestion are good and now I have to decide how to proceed.