Default voltage of dimmer output not reading same on two different DVM's

On Friday, April 9, 2021 at 12:19:10 AM UTC-7, wrote:
wrote:
============================

This blows Phil's statement out the water which is rare, there is no TRMS in DC.


" true RMS " = DC equivalent value for the *heating* effect on a resistance.

Known. but a DC meter might not be set up for that.

** You are not paying proper attention.

DC voltage and true RMS voltage are equivalent.
DC meters read the average, DC value of a wave.


The voltage, though, for an LED lighting system is NOT
proportional to current; it's the current average that makes
the light output bright or dim. Neither average DC nor RMS
are suitable measures unless it's on a CURRENT scale rather than voltage.