View Single Post
  #1   Report Post  
Nick
 
Posts: n/a
Default Removing a floor joist, OK?

Hi,

My plumber tells me it's OK to take out any one floor joist, is this
true?

The floor right now is 16" on center, span 8'6" joists 2"x8".

He's removing an iron bath and fitting a shower and the drain lands in
a different place.

If I understand right he wants to cut out about 18" from the center of
one joist and add doubled 2"x8" braces before and after to the
neighbouring joists.
I'd have expected to double up the 2 neighbours but he says this isn't
needed. Possibly as it would be a pain in the ass to do as 2 water
pipes pass thru both which I assume would have to be cut and re
sweated.

Thanks

Nick..