On 20/09/2020 11:13, Martin Brown wrote:
On 20/09/2020 09:20, jeff Layman wrote:
On 20/09/2020 01:57, John Rumm wrote:
On 19/09/2020 21:03, ss wrote:

Mini lathe 50 odd years old, the motor not original.
I would like to reduce the size of the electric box.
It contains an on off switch, an indicator lamp, and a reverse switch.
Inside is a large capacitor which takes up the space if I can replace
the capacitor with a smaller dimension then I can reduce the elec
box size.
Is a more modern one smaller and if so what sort of ratings am I
looking
for on eBay?

Image:
https://imgur.com/igFcKqj

It looks like a 4 uF motor run cap.

Something like:

https://cpc.farnell.com/ducati/4-16-...un%20capacitor


claims to be 55mm tall, and 28mm diameter - so probably a bit smaller
than the one you have.


Why is a 440v AC capacitor being used with a 230/250V motor?The OP did
say the motor had been replaced, so maybe it was a 440V (3 phase?)
motor previously, although that seems a bit strange for a mini-lathe.
Anyway, that capacitor is well past its sell-by date if the "1966" on
it is accurate. I haven't checked, but a 240V capacitor should be even
smaller.


The capacitor has to survive being attached to 240 rms ac mains voltage
which has peaks 1.4x higher and with a margin for the odd glitch.

This site labours the point a bit but shows the difference.

https://www.electronics-tutorials.ws...s-voltage.html


What if the cap is charged up one cycle and power is applied with the
other cycle. That wound mean you need a 750V cap

--