View Single Post
  #4   Report Post  
Posted to sci.electronics.repair
bitrex bitrex is offline
external usenet poster
 
Posts: 89
Default Problem with Tekpower PSU

On 8/11/2020 8:36 AM, legg wrote:
On Tue, 11 Aug 2020 03:54:01 -0400, bitrex wrote:

On 8/11/2020 3:41 AM, bitrex wrote:
Problem with my Tekpower PSU:

https://tekpower.us/downloadable/download/sample/sample_id/1/

Here's a teardown on YouTube:

https://youtu.be/Nfe28vGW6Ik

Problem is it's developed a fault where the current meter always reads 0
when in constant-voltage mode. Everything else seems to work fine and
it's putting out the right voltages, current limit works fine, when load
current exceeds the set point it current limits OK and shows the correct
value. Drop back and the display reads 0, again.

snip

Have you replaced the OP07?

Could be one output is unable to pull in one direction.

Or N18A . . .

Biasing to V13 doesn't look right, in the schematic, so
you may have to deal with some typos there.

RL


Yeah the diagnostic process is definitely not helped by the sloppy and
confusing schematic. Before I jump into op-amp swapping I'm trying to
understand how the current-sensing works in CV mode and is read by the
processor so maybe I can trace it back, but I'm not very familiar with
the PIC. Maybe it's reading the value from the "CCP" pin somehow that
"VIS" connects to, pin 19, but the impression I got from the datasheet
is those are some kind of comparator inputs for the
over-current/over-voltage sensing, not ADCs. Not sure.

Like a lot of gear from China at this price point it's designed to meet
a budget, but not badly designed to meet a budget and otherwise neatly
constructed, but then often let down by some sketchy soldering on the
connectors and through-hole parts. Often can "fix" this stuff by tapping
the board to find the intermittent joint or just re-touching all the
connectors but my first round of that didn't work, this time.