Baku 601D hot air reflow station - warning
In article ,
says...
I had a Baku 601D hot air reflow soldering station smoke
on my bench over the weekend, with all switches 'off'.
It's not CSA or UL (or anything else)
It was a transformer failure. None of the front panel
switches actually disconnect the line. Only protection
was an 8A fast blow fuse. It had blown sometime before
the plug was pulled, so I guess it did its job.
The hot air gun is directly live through a triac circuit
at all times that it's plugged in.
I've rewound a new transformer, with a thermal link, higher
temperature bobbin/wire. It will have its own fuse.
Will also repurpose one of the front panel switches to
disconnect the AC line and add a ground wire on the line
cord.
Sounds like a lot of work for a $ 50 device.
I have a 862D that is in the same price range. It does have a switch on
the back that cuts off all the power. They are on ebay for around $ 55
depending on who you buy from.