On 27/01/2020 18:30, Andy Burns wrote:
Grumps wrote:

Is it OK, in terms of building regs etc, to have a Schuko 16A socket
on a radial from the CU?

I know I can get a proper home charge point installed, but that's not
the cheapest option.


The schuko straight off the CU, by itself wouldn't give you proper
earthing for an EV.


In a garage, its arguable you could skip making it TT. The charge lead
will often include the type A RCD.


--
Cheers,

John.

/================================================== ===============\