View Single Post
  #3   Report Post  
Posted to uk.d-i-y
Jimk Jimk is offline
external usenet poster
 
Posts: 866
Default Cooker hood breeze

polygonum_on_google Wrote in message:
In our kitchen we have a perfectly ordinary cooker hood vented outside. Trouble is, there is quite a draught from it. It exits into the gap between our house and our neighbours' - which can be pretty windy. Fine when cooking, but makes the whole kitchen a bit chilly in the winter.

Is there a simple (but effective) way of reducing airflow when we are not using it?

Obviously we could shove a rolled up newspaper in the hole - but that is hardly convenient!


Does it have "back draft shutters" fitted?
They are thin light plastic spring loaded flaps (usually a pair,
each semi circular) usually mounted immediately before the
ducting connects to the fan output spigot.

They are pushed open by airflow from the fan being on, then when
fan is off they shut due to their springs. You usually hear them
as they "slap" shut after the fan is switched off...

--
Jimk


----Android NewsGroup Reader----
http://usenet.sinaapp.com/