On 01/08/2019 20:43, Graham. wrote:
John Rumm Wrote in message:
Regular readers may recall the eventual diagnosis of a leaking main heat
exchanger on my boiler. However that was winter and it was easier to top
it up each day than fix it then!

So I fixed it the other day, and took some photos and made some notes
along the way in case it helps anyone with a similar problem:

http://wiki.diyfaq.org.uk/index.php/...lus_624_repair


Great writeup John, filed away locally.
I have the 832 combination version and some very soft water to go
in it :-)
One question (for now).
Does the right hand side panel give access to anything important?


I think the short answer is "no"...

I have 45mm clearance to the side of the cupboard on the left side
but only 5mm on the right


There is nothing much of interest on the right - most of it is taken up
by the expansion vessel, and the outlet of the pump and condensate drain
is easy enough to get at from the front.

(I stuck in a picture of an 824 about half way down - so you can see the
layout of those - i.e. basically the same with the addition of a PHE,
and diversion valve).





--
Cheers,

John.

/================================================== ===============\