View Single Post
  #24   Report Post  
Posted to uk.d-i-y
Fredxx[_3_] Fredxx[_3_] is offline
external usenet poster
 
Posts: 3,157
Default Electronics funny.

On 13/04/2019 13:00, Dave Plowman (News) wrote:
Three way speaker driven by three power amplifiers all balanced input.
Crossover Behringer CX3400 analogue type which sounded not bad at all.

Wanting to experiment further, got a Behringer DCX2496 which is a direct
substitute, but digital, so allows a choice of crossover curves, delays to
each unit, and EQ too.

First impression, setting it to the same as the analogue one, was no
audible difference, which is good.

But slowly, when left on, it developed a buzz from the speaker(s) Loud
enough to be annoying.

Approach the speaker and the buzz drops in level and get close enough and
it goes. So you can play it with a hand rather like a Theramin. ;-)

Thinking it faulty, got another. Same thing. Swapped back to the analogue
one - fine.

Mains grounds and XLR grounds all check out OK.

Difficult to tell if the buzz is from all three speaker units, as when you
get your ear close enough to each one, it stops.

If you power up with no signal, no buzz (at least for over an hour). With
signal, it starts after a few minutes.

Any educated guesses? I've never come across anything like this before.


Have you considered getting some clamp-on ferrites to remove common mode
signals? If there are earth currents flowing it can only help.

They are best for high frequencies, but the fact you hear a buzz rather
than hum I'm wondering if suppression within the switch mode power
supply is placing hf currents into the earth path.