Thread: TRV failure
View Single Post
  #6   Report Post  
Andy Hall
 
Posts: n/a
Default TRV failure

On Fri, 26 Dec 2003 22:36:44 +0000, lid wrote:

On Fri, 26 Dec 2003 21:53:28 -0000, "Peter Taylor"
wrote:

"Grunff" wrote in message
...


Take the top off and push the sprung pin in - does it move? If
not, tap it *gently* with a hammer. Does it move now?


On my Drayton valve (the one with a shiny chrome head) turning the valve off
pushes the pin in. Sometimes it gets stuck and to open it again I pull the pin
up with a pair of pliers


OK it's a Drayton trv 4, how do I get the top off? It doesn't come
with a pull.


Undo the knurled ring immediately below the white plastic body

Turn it anticlockwise as you look down from above.

The pin will be sticking up out of the centre of the valve base
underneath.

The pin will not move by a great deal - no more than 3-5mm




..andy

To email, substitute .nospam with .gl