View Single Post
  #35   Report Post  
Posted to sci.electronics.repair
Ralph Mowery Ralph Mowery is offline
external usenet poster
 
Posts: 4,228
Default Replacing Large Electrolytics

In article , says...

I still believe in just replacing the 'bad' ones. Sometimes more harm
can be done to the equipment by doing the reforming process if done
wrong.


I don't think you've read the thread right through. These are NOS caps
out of circuit. I've now reformed them all and they pass all the
applicable tests, so I'll be installing them in place of the dead ones
later this week.





It may be worth while on the NOS caps. I may even be tempted to give
that a try.