On 17/08/2018 12:28, Roger Hayter wrote:
Clive Arthur wrote:

On 17/08/2018 11:34, wrote:
On Friday, 17 August 2018 11:19:33 UTC+1, Clive Arthur wrote:

I've just cut a bog standard IEC power lead with moulded plugs so I can
shorten it. There is no earth wire, and no indication that there is no
earth wire.

I'm aware that most things don't use the earth, but can this be legal?

Cheers

depends which tye of IEC lead it is. If it's a 3 pin connector, no. If 2
pin, yes.


NT

Yes, normal 3 pin with moulded 13A plug and moulded three pin C13 IEC
socket. All the usual BS approval markings, just no earth wire.
Looking at the cable, it does say, among other things, 'KEMA-KEUR
300/300V 2X0.75mm2'

Of course, I don't know where it came from, it's one of many.

Cheers


Thanks for drawing our attention to the existence of such things. Apart
from the potential electrocution danger, using one when expecting an
earth could lead to all sorts of problems with signal circuits,
including audio, and perhaps unexpected ESD problems. I am tempted to
go and check all mine immediately.


I have half a dozen more hanging up, they're all ok though I haven't
checked the ones in use. The illegal cable is noticeably thinner than
the others, at about 5.5mm diameter as opposed to 7mm.

Cheers
--
Clive