View Single Post
  #10   Report Post  
Rick Hughes
 
Posts: n/a
Default Alarm Bell Box wiring


The Response Sounder doesn't have "Strobe" connections, so you can miss

them out.

The negative - from the control panel is connected to the COM

The positive + from the control panel is connected to the Charger

The Tamper is connected to either a positive or negative return in the

control panel. You'll have to tell
the panel what the bell box uses in the programming, and find out with a

test meter which signal of tamper
in the bell box sends back to the panel.

You'll need a switched connection from the control panel, either positive

or negative dependant on which
makes the Siren work, from the control panel to the Siren terminal in the

bell box. You might be able to
use the Strobe or Switched Bell connection from the control panel to make

this work.

Hope this helps.



It has certainly given me something to try - time to annoy neighbours with
alarm sounding while I try again.


Thanks

Rick