Alarm Bell Box wiring
The Response Sounder doesn't have "Strobe" connections, so you can miss
them out.
The negative - from the control panel is connected to the COM
The positive + from the control panel is connected to the Charger
The Tamper is connected to either a positive or negative return in the
control panel. You'll have to tell
the panel what the bell box uses in the programming, and find out with a
test meter which signal of tamper
in the bell box sends back to the panel.
You'll need a switched connection from the control panel, either positive
or negative dependant on which
makes the Siren work, from the control panel to the Siren terminal in the
bell box. You might be able to
use the Strobe or Switched Bell connection from the control panel to make
this work.
Hope this helps.
It has certainly given me something to try - time to annoy neighbours with
alarm sounding while I try again.
Thanks
Rick
|