Lighting wiring centres
On 06/05/18 20:50, Andy Burns wrote:
Mike Clarke wrote:
All the contacts an a Wago connector are commoned, So for you can join n
conductors together in a n way Wago connector.
I know that 'standalone' wagos like the 222- series are commoned, but I
Tim was talking about a different series for DIN mounting (2001- Topjob
perhaps?)
Yes - another way is to use a random enclosure (even a double backbox
and blacking plate) and a bunch of free terminals. Quite common and
suits some applications.
I like DIN if it's a big and complicated wiring centre, just as it
allows a clean and more easily documented layout - but if it's a few
conductors, lever Wagos in regular box or Wiska box works well too.
|