View Single Post
  #7   Report Post  
Posted to alt.home.repair
Clare Snyder Clare Snyder is offline
external usenet poster
 
Posts: 4,564
Default Small, Slider Type SPST "Slider" Switches: Reliability Of ?

On Sun, 1 Apr 2018 19:20:39 -0600, rbowman wrote:

On 04/01/2018 01:33 PM, Robert11 wrote:
Hello,

Just would like opinions on this.

Have a slider switch (typical, small, 2 position kind) on a home furnace
relay box.

Switch position allows for either normal running of the furnace, or, in the event of a power loss,
to operate as a gravity system between the high and low temp. limits of the furnace.
Called a millivolt system.

So, this slider switch, being about 15 years of age now, gets very, very, little use.
Maybe once or so per year.

Just took the relay box apart, and the switch has lost the ability to make electrical contact anymore.

Surprising.

Is this more or less "typical" for these small slider type switches ?

What actually happens: contacts get oxidized, or...?


It's a common problem for dry circuits (very little current or voltage
across the contacts). Relays and switches meant for those sort of
applications often have gold plated contacts or are designed with a
wiping action across the contacts.

Are the contacts exposed or is the switch sealed? Back in the day of
backplanes with edge connectors, the Pink Pearl fix was the first thing
to try. Pink Pearl is a name for a Papermate eraser which worked very
well for removing oxidation from the fingers on the circuit board.


The old-tyme TV tuner cleaner works well - or De-Ox_it. Squirt,
operate the switch 50 times or so and try it.