Alarm Bell Box wiring
On Fri, 19 Dec 2003 21:57:05 +0000 (UTC), "Rick Hughes"
wrote:
Hope someone can help ...
My existing alarm panel (A1 Alarms RF8000) has failed, now bought a
complete replacement RESPONSE RE 3000, I want to use my existing Bellbox,
and not have to install the box which came with the kit .... my house has
been sold and I will be moving out.
To avoid having to replace the bell box, I would like to wire in the
new RESPONSE RE3000 to use the RF8000 bell
box.
However I am confused as to what I connect to what.
The A1 alarm used 6 cores to the bell box :
Colour alarm panel id Bellbox id
Green - 0 -
White - RT Return
Black - Bell - sw -
Red - Bell + +
Blue - Strobe - Strobe
Yellow - Strobe + Strobe
The RESPONSE only uses 4 wires ..
Red - Siren
Black - COM
Yellow - Charge
Blue - Tamper
There are 5 other unused connections - NO, C, NC, Power -, Power +
Anybody know how to connect the existing A1 alarm box up to the
Response
Looks like the existing bellbox doesn't have an internal battery, or
at least not a rechargeable one.
I'd try connecting Bell + and Strobe + to SIREN, Bell- and strobe- to
COM.
Connect Return to Tamper. If the system won't come out of tamper,
follow the panel instructions for a bell without tamper connection.
--
Niall
|