On Friday, 2 February 2018 19:52:07 UTC, ss wrote:
On 02/02/2018 18:52, tabbypurr wrote:
Ok now waiting on replacement fuse & holder for the other charger,
fingers crossed.
worth replacing the 4 mains diodes if you know how, those are the most likely cause.
Readings from diodes, hope it makes sense:
https://imgur.com/a/zxgxH
Well, sort of. Normally on the diode range the meter reports the Vf of the diode. However the bottom right one is clearly very different to the others, so it looks like they're suspect. One shorted diode could be enough to take out a fuse.
NT