In article ,
John Rumm wrote:
Generally its better to have lights on each floor energised from the
circuit that powers that floor. (even though the switch positions may
have a gang that is made live from a different circuit - that is more
"expected" than having a lamp fitting live from a different circuit.


I have all the corridor lights on their own circuit. Which then allows
working lights from a room should it trip. Also means all the switches on
one plate are on the same circuit. Not the most economical way to wire
things, though.

--