Analogue moving coil meter range extension?
"T i m" wrote in message
...
Hi All,
Not a 'repair' question as such but I was thinking of using an old
skool 250uA FSD moving coil panel meter to read the 10 to 15V DC range
(a lead acid battery charge / discharge indicator), next to a 0-30A
Ammeter (inc shunt etc).
I was thinking of using either a voltage reference such as
LM4040DIZ-10.0 or could I get away with a simple zener (BZX55C?) with
associated resistor(s) please?
Most people just use a Zener and maybe a few normal (or SB) forward volt
drops to trim the offset.
I was thinking the TL431 programmable Zener could be calibrated to exactly
what you need - but it needs a minimum current through it (possibly 1mA or
so).
You can probably incorporate a TL431 into some kind of bridge circuit with
the movement spanning the 2 arms, but it will almost certainly need some
kind of power supply.
|