On Wed, 9 Aug 2017 14:02:47 -0500, Terry Coombs
wrote:
I have one that's not feeding well , and wonder if it can - and
should - be cleaned . I have a new one on hand , but it's sized for
.035-.045 wire , and I usually use .025 solid . I have .035 flux core
loaded right now , but that was for an outside job that was blowing my
shield gas away and I'd much prefer to go back to solid - I also have
some .030 on hand but haven't yet tried it .
--
Snag
They can be cleaned..assuming its actually dirty enough to be an
issue. Most often..they have a kink in the liner somewhere.
Clean em by spoozing kerosene through the liner with compressed air,
after giving them a bit of a soak in a coffee can filled with kerosene
(or diesel etc etc)
---
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus