On 07/03/2017 05:57 AM, frank wrote:
Hi all,
I was trying my Heathkit curve tracer on a gas discharge transient suppressor
(striking at about 200V) and I've found the following behaviour:
https://www.youtube.com/watch?v=DeKPkG5T1xc
Basicly it seems to heavily ring on the turn-off curve?
This kind of devices should just show a two lines curve in theory.
My curve tracer appears to work fine on other less exotic devices (BJT,
zeners).
Can someone explain what is happening?
Thanks
Frank IZ8DWF
Maybe Barkhausen oscillation (aka the Barkhausen-Kurtz effect). This
used to show up in old-fashioned incandescent light bulbs that were
evacuated instead of argon-filled.
Cheers
Phil Hobbs
--