Behringer VT1951 Tube Ultra-Q repair
On 06/06/2017 04:24 AM, Phil Allison wrote:
bitrex wrote:
----------------
Phil Allison wrote:
** The only way to explain your results is that there is a low impedance path between the plates of the tube - maybe just after the coupling caps.
So not faulty components, a PCB issue.
Cleaning the area with a good PCB solvent is a sensible first step.
Fixed, cause was crudded up/flaky solder joints on the interconnect
cable header coming from the tube board to the solid state section.
** I guess that is the nearest thing to "thanks" I'm gonna get ....
..... Phil
You're right, that was insensitive of me. Thank you, Phil - if I ever
have a chance to visit that part of the world I'll know where to take my
stuff.
Accents sound kinda funny, though. We all talk like this he
https://www.youtube.com/watch?v=bgfDALzpfJU
Probably sounds wicked retahded to anyone else.
|