Default Centrifugal pump question

wrote in message
...
On Monday, May 29, 2017 at 5:13:41 PM UTC-4, wrote:
On Monday, May 29, 2017 at 3:34:50 PM UTC-4,
wrote:
sw

Right. So what is the condition inside of one involute in the
second stage? Is it completely full when it's operating?

--
Ed Huntress



It is exactly the same as the first stage.

Dan


And what is that condition? Are the involutes completely filled?
And, if so, how is that possible unless the velocity is the same
from the input port to the periphery of the wheel?

--
Ed Huntress


How did you ever dream up that requirement? It isn't a positive
displacement pump. If the outlet valve is closed the input and output
velocities will be zero, yet the periphery is still spinning. The
pressure differential (p) from inlet to outlet will be what the
discharge curve shows for zero flow (q).