On 04/09/2017 9:11 AM, Jim Wilkins wrote:
"James wrote in message
news
Could you double-check my use of on-line calculators to determine the
column buckling load of a pinned-end chain link fence post 1.90" OD,
1.77" ID (16 gauge) and 96" long as 4900 lbs?
....
I get ~1600 lb and that's assuming fully axial loading with no
moment...will be significantly less with side loading. Seems on first
blush at a reasonable number, 8'L/2"D is a pretty long and slender
wand...and 16 ga ain't that stout.
--