Thread
:
Tubes in broken spotwelder & other questions
View Single Post
#
30
Posted to sci.electronics.repair
[email protected]
external usenet poster
Posts: 2,163
Tubes in broken spotwelder & other questions
On Wed, 16 Nov 2016 09:25:37 +0000, Geo
wrote:
On Mon, 14 Nov 2016 10:38:12 -0800,
wrote:
snip
The OA2WA tubes have only two of the pins connected. So power goes
in one pin and then out the other to the next OA2WA tube and so on. It
looks like there is no output from the last tube in the series. So
maybe this is why the caps won't charge.
snip
I cannot see properly from the photos - but is there a connection to
the last (bottom) regulator cathode?
I would guess it might be to chassis so "no output" is correct.
If all three glow then the voltage across each should be fine.
There is a connection. It does not go to the chassis. I think the tube
is bad. All tubes are gonna be replaced anyway.
Eric
Reply With Quote
[email protected]
View Public Profile
Find all posts by
[email protected]