Thread
:
Fan problem
View Single Post
#
7
Posted to sci.electronics.repair
[email protected]
external usenet poster
Posts: 1,625
Fan problem
On Tuesday, November 8, 2016 at 3:42:12 PM UTC-5, Jon Elson wrote:
wrote:
On Tuesday, November 8, 2016 at 7:21:17 AM UTC-5, N_Cook wrote:
Much Snippage
Questions:
a) What is the actual resistance in ohms of the OEM fan and the
replacement fan if measured across the contacts.
Meaningless. These fans have a commutation circuit and some FETs in them,
so you will not read anything that resembles a resistance on them.
Jon
No. The two that work ohm out at ~10 meg. The two that do not ohm out at ~20K. So, yes, you are seeing 'resistance' on them. Clearly "these fans" are not created equal.
Peter Wieck
Melrose Park, PA
Reply With Quote
[email protected]
View Public Profile
Find all posts by
[email protected]