View Single Post
  #8   Report Post  
Posted to uk.d-i-y
John Rumm John Rumm is offline
external usenet poster
 
Posts: 25,191
Default Worcester Bosch Greenstar boiler/hot water

On 12/04/2016 08:42, wrote:

Now here's the thing; if water is drawn simultaneously from a hot
outlet and certain cold outlets and/or a second hot outlet, the
boiler can usually be made to fire-up and away we go. In some cases,
closing off those additional outlets causes the hot water to wane.


What do you think? Worth a try, or total waste of time?


It sounds like the flow / diaphragm switch that detects the flow of hot
water is not working as it should.


--
Cheers,

John.

/================================================== ===============\
| Internode Ltd -
http://www.internode.co.uk |
|-----------------------------------------------------------------|
| John Rumm - john(at)internode(dot)co(dot)uk |
\================================================= ================/